压接另一端线芯。将接头外护套管套在剥切短端—4电缆上,并在每相线芯上分别套E屏蔽铜丝网,再将短端电缆每相线芯导体分别插入已压接在长端电缆每相线芯-9-~~的连接管内,进行压接,除去飞边和毛刺,用清洁布擦净电缆绝缘表面、半导电层表面及导体连接管表面。
Crimp the core at the other end. The outer protective sleeve of the joint is sleeved on the stripped short end-4 cable, and the e-shielded copper wire mesh is sleeved on each phase core of the short end cable, and then the conductor of each phase core of the short end cable is respectively inserted into the connecting pipe crimped on each phase core-9 - ~ of the long end cable for crimping, the flash and burr are removed, and the insulation surface, semi-conductive layer surface and conductor connecting pipe surface of the cable are wiped with a clean cloth.
将接头预制件移到接头位置。在短端电缆绝缘表面上均匀地涂一层硅脂,然后将领套在长端电缆线芯上的接头预制件拉到接头位置,要保证预制件内两端的应力锥半导电层正好分别搭盖在两端电缆绝缘外半导电层末端上,具体尺寸按制造厂提供的安装说明书规定。
6. Move the joint preform to the joint position. Apply a layer of silicone grease evenly on the insulation surface of the short end cable, and then pull the joint preform sleeved on the long end cable core to the joint position. Ensure that the stress cone semi-conductive layers at both ends of the preform are just overlapped on the ends of the outer semi-conductive layers of the cable insulation at both ends, and the specific dimensions shall be in accordance with the installation instructions provided by the manufacturer.